<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "journalpublishing3.dtd">
<article article-type="research-article" dtd-version="3.0" xml:lang="en" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">	<front>
		<journal-meta>
			<journal-id journal-id-type="publisher-id">SJAR</journal-id>
			<journal-title-group>
				<journal-title>Spanish Journal of Agricultural Research</journal-title>
				<abbrev-journal-title>SJAR</abbrev-journal-title>
			</journal-title-group>
			<issn pub-type="epub">2171-9292</issn>
			<publisher>
				<publisher-name>Instituto Nacional de Investigación y Tecnología Agraria y Alimentaria (INIA)</publisher-name>
			</publisher>
		</journal-meta>
		<article-meta>
			<article-id pub-id-type="publisher-id">7517</article-id>
			<article-id pub-id-type="doi">10.5424/sjar/2016141-7517</article-id>
			<article-categories>
				<subj-group subj-group-type="heading">
					<subject>Research Article</subject>
				</subj-group>
			</article-categories>
			<title-group>
				<article-title>Surplus thermal energy model of greenhouses and coefficient analysis for effective utilization</article-title>
				<alt-title alt-title-type="running-head">Surplus thermal energy model of greenhouses and its coefficient analysis</alt-title>
			</title-group>
			<contrib-group>  
			<contrib contrib-type="author" corresp="no">
					<name>
						<surname>Yang</surname>
						<given-names>Seung-Hwan</given-names>
					</name>
					<aff>Korea Institute of Industrial Technology, Convergence Agricultural Machinery Group. Jeonju 54853. Republic of Korea.</aff>
				</contrib>
				<contrib contrib-type="author" corresp="no">
					<name>
						<surname>Son</surname>
						<given-names>Jung-Eek</given-names>
					</name>
					<aff>Seoul National University, Dept. Plant Sci. / Research Institute for Agriculture and Life Sciences. Seoul 08826. Republic of Korea.</aff>
				</contrib>
				<contrib contrib-type="author" corresp="no">
					<name>
						<surname>Lee</surname>
						<given-names>Sang-Deok</given-names>
					</name>
					<aff>Gyeonggido Agricultural Research &amp; Extension Services, Climate Change Response Team. Hwaseong-si, Gyeonggi-do 18388. Republic of Korea.</aff>
				</contrib>
			<contrib contrib-type="author" corresp="no">
					<name>
						<surname>Cho</surname>
						<given-names>Seong-In</given-names>
					</name>
					<aff>Seoul National University, Dept. Biosyst. Biomat. Sci. Eng. / Research Institute for Agriculture and Life Sciences. Seoul 08826. Republic of Korea.</aff>
				</contrib>
				<contrib contrib-type="author" corresp="no">
					<name>
						<surname>Ashtiani-Araghi</surname>
						<given-names>Alireza</given-names>
					</name>
					<aff>Seoul National University, Dept. Biosyst. Biomat. Sci. Eng. Seoul 08826. Republic of Korea.</aff>
				</contrib>
				<contrib contrib-type="author" corresp="yes">
					<name>
						<surname>Rhee</surname>
						<given-names>Joong-Yong</given-names>
					</name>
					<aff>Seoul National University, Dept. Biosyst. Biomat. Sci. Eng. / Research Institute for Agriculture and Life Sciences. Seoul 08826. Republic of Korea.</aff>
				</contrib>
				</contrib-group>
			<author-notes>
				<corresp>should be addressed to Joong-Yong Rhee: <email xlink:href="jyr@snu.ac.kr">jyr@snu.ac.kr</email></corresp>
			</author-notes>
			<pub-date pub-type="epub">
				<day>31</day>
				<month>03</month>
				<year>2016</year>
			</pub-date>
			<pub-date pub-type="collection">
				<year>2016</year>
			</pub-date>
			<volume>14</volume>
			<issue>1</issue>
			<elocation-id content-type="doi">10.5424/sjar/2016141-7517</elocation-id>
			<history>
				<date date-type="recibido">
					<day>09</day>
					<month>02</month>
					<year>2015</year>
				</date>
				<date date-type="aceptado">
					<day>03</day>
					<month>02</month>
					<year>2016</year>
				</date>
			</history>
			<permissions>
				<copyright-statement>© 2016 INIA</copyright-statement>
				<copyright-year>2016</copyright-year>
				<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/3.0/">
					<license-p>This is an open access article distributed under the Creative Commons Attribution License (CC by 3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
				</license>
			</permissions>
			<abstract  id="abstract01">
				<title>Abstract</title>
				<p>If a greenhouse in the temperate and subtropical regions is maintained in a closed condition, the indoor temperature commonly exceeds that required for optimal plant growth, even in the cold season. This study considered this excess energy as surplus thermal energy (STE), which can be recovered, stored and used when heating is necessary. To use the STE economically and effectively, the amount of STE must be estimated before designing a utilization system. Therefore, this study proposed an STE model using energy balance equations for the three steps of the STE generation process. The coefficients in the model were determined by the results of previous research and experiments using the test greenhouse. The proposed STE model produced monthly errors of 17.9%, 10.4% and 7.4% for December, January and February, respectively. Furthermore, the effects of the coefficients on the model accuracy were revealed by the estimation error assessment and linear regression analysis through fixing dynamic coefficients. A sensitivity analysis of the model coefficients indicated that the coefficients have to be determined carefully. This study also provides effective ways to increase the amount of STE.</p>
				</abstract>
			<kwd-group>
				<title>Additional key words</title>
				<kwd>energy balance</kwd>
				<kwd>energy conservation</kwd>
				<kwd>environmental control</kwd>
				<kwd>heat pump</kwd>
				<kwd>heat storage</kwd>
			</kwd-group>
			<kwd-group>
				<title>Abbreviations used</title>
				<kwd>FCU (fan coil unit)</kwd>
				<kwd>HST (high temperature heat storage tank)</kwd>
				<kwd>LST (low temperature heat storage tank)</kwd>
				<kwd>m<italic>PLAI</italic> (modified <italic>PLAI</italic>, ratio of total projected leaf area to the floor area)</kwd>
				<kwd><italic>PLAI</italic> (projected leaf area index, projected area of horizontal leaves per unit of horizontal land below)</kwd>
				<kwd>SHEF (sensible heat emission factor)</kwd>
				<kwd>STE (surplus thermal energy)</kwd>
			</kwd-group>
			<funding-group>
			<funding-statement>This study was supported by the Bio-industry Technology Development Program, Ministry of Agriculture, Food and Rural Affairs, Republic of Korea.</funding-statement>
			</funding-group>
		</article-meta>
		<notes>
		<p><bold>Competing interests:</bold> The authors have declared that no competing interests exist.</p>
		</notes>
	</front>
	<body>
		<sec id="S1">
			<title>Introduction</title>
			<p>Modern greenhouses control plant growth conditions, such as temperature, humidity, carbon dioxide concentration, light and nutrients, and produce high-quality products irrespective of the outdoor climate. However, controlling the climate requires a large amount of energy, especially for heating during the cold season. The energy costs diminish the benefits of greenhouse farming, and the use of fossil fuels for the energy contributes to global warming. Therefore, many studies have been conducted to reduce the use of fossil fuels and conserve energy for greenhouse operation. Solar energy is a representative renewable and sustainable energy for greenhouse heating (<xref ref-type="bibr" rid="CIT0028">Ozgener &amp; Hepbasli, 2005</xref>; <xref ref-type="bibr" rid="CIT0032">Sethi &amp; Sharma, 2008</xref>; <xref ref-type="bibr" rid="CIT0007">Benli &amp; Durmuş, 2009</xref>; <xref ref-type="bibr" rid="CIT0012">Fabrizio, 2012</xref>; <xref ref-type="bibr" rid="CIT0027">Ntinas <italic>et al.</italic>, 2014)</xref>.</p>
		<p>This study concentrates on the utilization of surplus thermal energy (STE) in greenhouses. Even in the cold season, the thermal energy input from solar radiation easily exceeds the required amount for heating on a clear day in the temperate or subtropical regions. This excessive solar energy is regarded as STE. There are several studies related to the STE energy (<xref ref-type="bibr" rid="CIT0030">Pavlou, 1991</xref>; <xref ref-type="bibr" rid="CIT0035">Suh <italic>et al.</italic>, 2009</xref>). This STE energy can be efficiently utilized with closed greenhouses (<xref ref-type="bibr" rid="CIT0005">Bakker <italic>et al.</italic>, 2006</xref>; <xref ref-type="bibr" rid="CIT0037">Vadiee &amp; Martin, 2012</xref>, <xref ref-type="bibr" rid="CIT0038">2013a</xref>,<xref ref-type="bibr" rid="CIT0039">b</xref>). <xref ref-type="bibr" rid="CIT0041">Yang <italic>et al. </italic>(2012a)</xref> investigated the daily change of greenhouse indoor temperatures and designed a greenhouse system to utilize STE using a heat pump system, which recovers and stores STE and then supplies it when necessary. This system operated in a greenhouse having a 100 m<sup>2</sup> floor area and recovered 8.71 GJ for 3 months in a cold season (<xref ref-type="bibr" rid="CIT0040">Yang &amp; Rhee, 2013</xref>). The economic feasibility of STE depends on the amount of it compared with the cost of its utilization system. Thus, estimating the amount of STE is inevitably necessary when deciding on the installation of the STE utilization system. Many studies on greenhouse thermal modeling have been conducted considering environmental control systems (<xref ref-type="bibr" rid="CIT0033">Sharma <italic>et al.</italic>, 1999</xref>; <xref ref-type="bibr" rid="CIT0010">Chou <italic>et al.</italic>, 2004</xref>; <xref ref-type="bibr" rid="CIT0011">Hepbasli, 2011</xref>), thermal curtains and earth-air heat exchangers (<xref ref-type="bibr" rid="CIT0034">Shukla <italic>et al.</italic>, 2006</xref>), neural network or computer-aided modeling (<xref ref-type="bibr" rid="CIT0013">Ferreira <italic>et al.</italic>, 2002</xref>; <xref ref-type="bibr" rid="CIT0017">Han <italic>et al.</italic>, 2009</xref>), the effect of greenhouse orientation (<xref ref-type="bibr" rid="CIT0031">Sethi, 2009</xref>), solar energy (<xref ref-type="bibr" rid="CIT0016">Hamdan <italic>et al.</italic>, 1992</xref>; <xref ref-type="bibr" rid="CIT0001">Abdel-Ghany &amp; Al-Helal, 2011</xref>), and thermal storages (<xref ref-type="bibr" rid="CIT0014">Gauthier <italic>et al.</italic>, 1997</xref>; <xref ref-type="bibr" rid="CIT0026">Najjar &amp; Hasan, 2008</xref>; <xref ref-type="bibr" rid="CIT0023">Lee <italic>et al.</italic>, 2011</xref>; <xref ref-type="bibr" rid="CIT0037">Vadiee &amp; Martin, 2012</xref>). In this study, a thermal model for the greenhouse was adopted into a test greenhouse including an STE utilization system. To fit the model at high accuracy, several coefficients related to environmental status, greenhouse structural specification, control conditions and characteristics of crops were considered. Using the determined STE model, the coefficients that mostly affect the model accuracy were investigated, and a sensitivity analysis on the coefficients were conducted. We propose effective methods for estimating the amount of STE and its utilization.</p>
		</sec>
		<sec id="S2">
			<title>Material and methods</title>
			<sec id="S2.1.">
				<title>Test greenhouse equipped with the STE utilization system</title>
				<p>The test greenhouse was single span, and the covering material was double-layer glass with 7 mm thickness. The floor area was 99.36 m<sup>2</sup> with a width of 6.9 m and 14.4 m in length. The wall and the ridge were 3.4 m and 5.1 m high, respectively. Accordingly, the covering area was 267.33 m<sup>2</sup>, and the interior volume was 422.28 m<sup>3</sup>. The greenhouse was at latitude 37.2° N, in an east-west orientation rotated 20° clockwise.</p>
		<p>The STE utilization system consists of a heat pump, low and high temperature heat storage tanks (LST and HST, respectively), and 10 fan-coil units (FCUs) as shown in <xref ref-type="fig" rid="F0001">Fig. 1</xref>. When STE is generated, it is recovered by circulating cold water in the LST to the FCUs in the greenhouse. STE absorbed into the cold water is transferred to the HST as hot water using the heat pump. When the greenhouse needs heating, the hot water in the HST circulates into the FCUs in the greenhouse. For more detail system information, refer to <xref ref-type="bibr" rid="CIT0041">Yang <italic>et al.</italic> (2012a)</xref>.</p>
		<fig id="F0001">
					<label>Figure 1.</label>
					<caption>
						<title>Schematic diagram of the surplus thermal energy utilization system and the sensor positions. Arrows show the thermal energy flow. Circles indicate the position of sensors of air temperature (T<sub>a</sub>), floor temperature (T<sub>f</sub>), water temperature (T<sub>w</sub>), water flow rate (F<sub>w</sub>) and solar radiation (I<sub>s</sub>).</title>
					</caption>
					<graphic xlink:href="sjar_e0202_f01.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
	</fig>
			</sec>
			<sec id="S2.2">
				<title>Greenhouse operation and data measurement</title>
				<p>The test greenhouse system was operated during the winter (December 2010 – February 2011). The cultivated plants were roses (<italic>Rosa hybrida</italic>) in pots, with 1200 pots laid on three growth trays. The set-points for the temperature control were 26°C in the day time and 16°C at night time. Thus, STE was recovered when the greenhouse indoor temperature exceeded 26°C. The amount of STE was calculated using <xref ref-type="disp-formula" rid="form0001">Eq. [1]</xref> by measuring the water temperature and flow rate.</p>
					<graphic id="form0001" xlink:href="sjar_e0202_form1.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<p>where <italic>E</italic><sub>gr</sub> is the energy amount that supplied for or recovered from the greenhouse; <italic>Q</italic><sub>wt</sub> is the water flow rate (m<sup>3</sup>/min); <italic>c</italic>
			<sub>wt</sub> and <italic>ρ</italic><sub>wt</sub> are the specific heat of water (J/kg/K) and the water density (kg/m<sup>3</sup>), respectively; <italic>t</italic><sub>en</sub> and <italic>t</italic>
			<sub>lv</sub> are the temperature (°C) entering and leaving the greenhouse at time <italic>T </italic>(min), respectively; <italic>f</italic><sub>m-s</sub> is the unit factor for converting from minute to second (60 s/min).</p>
		<p>The water flow rate and the water temperature were measured using a water flow meter (HMD40-1b, Shinil meter tech, Korea), accuracy ±2%, and temperature sensors (NTC-10kΩ), accuracy ±0.3°C. For the greenhouse indoor and outdoor temperatures, temperature sensors (PT-100Ω), accuracy ±0.3°C, with the fan-aspirated radiation shield (<xref ref-type="bibr" rid="CIT0042">Yang <italic>et al.</italic>, 2012b</xref>) were installed in the center 1.5 m above the floor in the greenhouse and 5.5 m above the ground beside the greenhouse. Solar radiation was measured using a pyranometer (SYE-420M2007PM4, Shinyoung, Korea). Specifications for the pyranometer are provided in <xref ref-type="table" rid="T0001">Table 1</xref>. The measurement points are presented in <xref ref-type="fig" rid="F0001">Fig. 1</xref>. Data were recorded every minute.</p>
	<table-wrap id="T0001">
		<label>Table 1.</label>
		<caption>
		<title>Pyranometer specifications.</title>
		</caption>
		<graphic xlink:href="sjar_e0202_t01.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
	</table-wrap>
			</sec>
			<sec id="S2.3.">
				<title>STE modeling</title>
				<p>The elements of the greenhouse energy balance for the STE model are shown in <xref ref-type="fig" rid="F0002">Fig. 2</xref>. Solar radiation (<italic>I</italic>
			<sub>s</sub>) transmits through the greenhouse covers, and its energy reduces. Total solar energy transmitted into the greenhouse (<italic>E</italic>
			<sub>so</sub>) is converted to sensible heat by the plants and floor (<italic>E</italic>
			<sub>input</sub>). If this sensible heat is greater than thermal energy loss of the greenhouse (<italic>E</italic>
			<sub>loss</sub>), the greenhouse contains the STE (<italic>E</italic>
			<sub>sp</sub>) as their difference. The detailed calculation procedure is elaborated in the following section.</p>
			<fig id="F0002">
					<label>Figure 2.</label>
					<caption>
						<title>Greenhouse energy balance for the STE model.</title>
					</caption>
					<graphic xlink:href="sjar_e0202_f02.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
	</fig>
			<sec id="S2.3.1.">
				<title>Solar energy input</title>
				<p>The energy input from solar radiation was determined by the covering areas, the ratios of the direct and the diffuse radiation to the global radiation, and light transmissivity of the covers. The ratios of the direct and the diffuse radiation to global radiation display a stable value at a specific location on a clear day (<xref ref-type="bibr" rid="CIT0003">Al-Mohamad, 2004</xref>; <xref ref-type="bibr" rid="CIT0002">Ahmed <italic>et al.</italic>, 2009</xref>). Therefore, the energy input from solar radiation, <italic>E</italic>
			<sub>so</sub>, is expressed as</p>
			<graphic id="form0002" xlink:href="sjar_e0202_form2.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<p>where <italic>A</italic>
			<sub>drt</sub> and <italic>A</italic>
			<sub>dff</sub> are the areas affected by direct and diffuse radiation, respectively; <italic>Φ</italic>
			<sub>drt</sub> and <italic>Φ</italic>
			<sub>dff</sub> are the ratios of direct and diffuse radiation to global radiation, respectively; <italic>I</italic>
			<sub>s</sub> is the intensity of global solar radiation; <italic>τ</italic>
			<sub>gh</sub> is the solar radiation transmissivity of greenhouse-covering materials; and <italic>T</italic> is time. Because the area affected by diffuse radiation (<italic>A</italic>
			<sub>dff</sub>) is equal to the total covering area (<italic>A</italic>
			<sub>cv</sub>), <xref ref-type="disp-formula" rid="form0002">Eq. [2]</xref> is simplified into</p>
				<graphic id="form0003" xlink:href="sjar_e0202_form3.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<p>where, <italic>f</italic>
			<sub>r </sub>
			<italic>= (A</italic>
			<sub>drt</sub>
			<italic>/A</italic>
			<sub>cv</sub>
			<italic>)Φ</italic>
			<sub>drt</sub>
			<italic>+Φ</italic>
			<sub>dff</sub>. In winter, when the solar altitude is low, direct radiation reaches approximately half of the total covering area, <italic>A</italic>
			<sub>drt</sub> = 0.5<italic>A</italic>
			<sub>cv</sub>. The ratio of diffuse radiation to global radiation (<italic>Φ</italic>
			<sub>dff</sub>) is 0.15 on a clear day, and thus, <italic>Φ</italic>
			<sub>drt</sub> = 0.85 (<xref ref-type="bibr" rid="CIT0020">Kim <italic>et al.</italic>, 1997</xref>), and <italic>f</italic>
			<sub>r</sub> becomes 0.575.</p>
		<p>The greenhouse covers <italic>τ</italic>
			<sub>gh</sub> varies according to the type, orientation and covering material of the greenhouse. The solar position and outside weather conditions also contribute to the <italic>τ</italic>
			<sub>gh</sub>. A variety of studies on the <italic>τ</italic>
			<sub>gh</sub> have considered the incidence angle of solar radiation (<xref ref-type="bibr" rid="CIT0008">Bowman, 1970</xref>), weather conditions (<xref ref-type="bibr" rid="CIT0024">Leonidopoulos, 2000</xref>; <xref ref-type="bibr" rid="CIT0009">Cabrera <italic>et al.</italic>, 2009</xref>), greenhouse orientation (<xref ref-type="bibr" rid="CIT0029">Papadakis <italic>et al.</italic>, 1998</xref>; <xref ref-type="bibr" rid="CIT0025">Li <italic>et al.</italic>, 2000</xref>), structural members (<xref ref-type="bibr" rid="CIT0011">Critten, 1987</xref>), and dust and dirt on the covering (<xref ref-type="bibr" rid="CIT0015">Geoola <italic>et al.</italic>, 1998</xref>). Because the results on <italic>τ</italic>
			<sub>gh </sub>vary from 25% to 59%, according to experimental conditions, applying a specific <italic>τ</italic>
			<sub>gh</sub> for the energy input equation was difficult. To resolve this difficulty in <italic>τ</italic>
			<sub>gh</sub> determination, factors affecting the <italic>τ</italic>
			<sub>gh</sub> were divided into the incidence angle of solar radiation and the dust/dirt of the covering. Thus, the overall <italic>τ</italic>
			<sub>gh</sub> of a greenhouse is expressed by</p>
			<graphic id="form0004" xlink:href="sjar_e0202_form4.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<p>where <italic>τ</italic>
			<sub>pd</sub> is the solar radiation transmissivity for the perpendicular beam on the surface, and <italic>f</italic>
			<sub>ang</sub> and <italic>f</italic>
			<sub>dd</sub> are the incidence angle factor and the dust/dirt factor for the solar radiation transmissivity, respectively.</p>
			</sec>
			<sec id="S2.3.2">
				<title>Conversion of solar energy input to thermal energy</title>
			<p>Solar radiation transmitted into a greenhouse reaches plants or the floor and converts to thermal energy. In here, coefficients to convert solar energy into thermal energy are considered, and they are designated the sensible heat emission factors (SHEFs). In particular, this factor for plants is related to the Bowen ratio, which is the ratio of the sensible heat loss to the evaporative heat loss (<xref ref-type="bibr" rid="CIT0036">Taiz &amp; Zeiger, 1991</xref>). Consequently, the amount of thermal energy in the greenhouse is expressed as</p>
		<graphic id="form0005" xlink:href="sjar_e0202_form5.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<p>where <italic>f</italic>
			<sub>sn-plt</sub> and <italic>f</italic>
			<sub>sn-flr</sub> are SHEFs for the plant and the floor, respectively; and m<italic>PLAI </italic>is the modified projected leaf area index. The m<italic>PLAI</italic> is the ratio of total projected leaf area to the floor area, which was modified by the <italic>PLAI</italic> concept (<xref ref-type="bibr" rid="CIT0006">Barclay, 1998</xref>). In this study, the test plant was rose in pots, which takes a small portion of the greenhouse inside volume. Thus, minor parameters such as latent heat, evaporation and plant respiration were intended to be integrated into the SHEF. If plants took a large portion of the greenhouse inside volume such as tomatoes and paprika, these parameters need to be considered.</p>	
			</sec>
			<sec id="S2.3.3.">
				<title>Thermal energy loss of the greenhouse</title>
				<p>For greenhouses with closed windows, thermal energy loss, <italic>E</italic>
			<sub>loss</sub>, occurs by convection, conduction and infiltration through the cover and the floor, which is expressed by</p>
		<graphic id="form0006" xlink:href="sjar_e0202_form6.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<p>where <italic>U</italic>
			<sub>gh</sub> is the overall heat transfer coefficient of the greenhouse including the infiltration effect, and <italic>f</italic>
			<sub>wind</sub> is the wind effect factor, which was set to 1.0 in this study. Although the wind effect factor is a linear function of wind speed, the effect of the wind speed is very small in the case of closed greenhouses with the double-layered glass covers except in strong winds (<xref ref-type="bibr" rid="CIT0020">Kim <italic>et al.</italic>, 1997</xref>); <italic>h</italic>
			<sub>flr</sub> is the heat transfer coefficient through the floor, and <italic>t</italic>
			<sub>in</sub>, <italic>t</italic>
			<sub>out</sub> and <italic>t</italic>
			<sub>flr</sub> are the temperatures of the greenhouse inside, outside and floor, respectively.</p>
			</sec>
			<sec id="S2.3.4">
				<title>STE model</title>
				<p>The STE model consists of three steps. The first step is to find the time that greenhouse heating is stopped by solar energy input. This relationship is expressed by</p>
		<graphic id="form0007" xlink:href="sjar_e0202_form7.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<p>where inside temperature (<italic>t</italic>
			<sub>in</sub>) in the thermal energy loss element (<italic>dE</italic>
			<sub>loss</sub>) becomes the heating temperature if the heating system normally operates; <italic>i</italic> is the time sequence in minutes. Because it took approximately one hour to convert solar energy input into thermal energy, thermal energy input was compared with thermal energy loss after one hour. This time difference was empirically found through temperature measurement.</p>
		<p>After the first step is satisfied, the indoor temperature is raised by the increase of solar energy. This is the second step, expressed by</p>
		<graphic id="form0008" xlink:href="sjar_e0202_form8.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<p>where the indoor temperature (<italic>t</italic>
			<sub>in</sub>) in the thermal energy loss element (<italic>dE</italic>
			<sub>loss</sub>) equals <italic>t</italic>
			<sub><italic>in</italic></sub>(<italic>i</italic> - 1); <italic>C</italic>
			<sub>gh</sub> is the heat capacity within the greenhouse. <xref ref-type="disp-formula" rid="form0008">Eq. [8]</xref> is calculated repeatedly until the indoor temperature is increased to the optimal growth temperature. The final <italic>i</italic> is the initial time that STE is generated.</p>
		<p>When the difference between the thermal energy input and loss is a positive value, STE exists. The amount of STE is calculated by <xref ref-type="disp-formula" rid="form0009">Eq. [9]</xref>, which is the final step of the STE model.</p>
		<graphic id="form0009" xlink:href="sjar_e0202_form9.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<p>where <italic>T</italic>
			<sub>1</sub> starts with the final <italic>i</italic> at the second step. <italic>T</italic>
			<sub>2</sub> is the time before the amount of STE calculated between <italic>i</italic>, and <italic>i</italic>+1 is the negative value. During cloudy days, many time-sections of <italic>T</italic>
			<sub>1</sub> and <italic>T</italic>
			<sub>2</sub> can be observed.</p>
			</sec>
			</sec>
			<sec id="S2.4">
				<title>Determination of coefficients in the STE model for the test greenhouse</title>
				<sec id="S2.4.1.">
					<title>Incidence angle factor for the solar radiation transmissivity</title>
					<p>The incidence angle factor for the solar radiation transmissivity was determined based on <xref ref-type="bibr" rid="CIT0008">Bowman (1970)</xref>. The solar radiation transmissivity was between 0.92 and 1.0 for incidence angles of less than 60°, whereas solar radiation was reduced exponentially as incidence angle increased above 60°.</p>
		<p>The incidence angle of solar radiation on the greenhouse covering, <italic>α</italic>
			<sub>i</sub>, was calculated using</p>
		<graphic id="form0010" xlink:href="sjar_e0202_form10.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<graphic id="form0011" xlink:href="sjar_e0202_form11.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<graphic id="form0012" xlink:href="sjar_e0202_form12.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<p>where <italic>δ</italic> is the declination of the sun and <italic>n</italic>
			<sub>day</sub> the day of the year, for example, <italic>n</italic>
			<sub>day</sub> on March 1 is 60; <italic>α</italic>
			<sub>h</sub> is the solar altitude angle; <italic>φ</italic> the greenhouse latitude; <italic>α</italic>
			<sub>t</sub> the hour angle (noon = 0); and <italic>θ</italic> the inclined angle of the surface; <italic>α</italic>
			<sub>a</sub> is the surface azimuth angle; and <italic>α</italic>
			<sub>b</sub> the solar azimuth angle.</p>
				</sec>
			<sec id="S2.4.2.">
				<title>Heat transfer coefficients of the greenhouse</title>
				<p>The overall heat transfer coefficient through the cover, <italic>U</italic>
			<sub>gh</sub>, and the heat transfer coefficient through the floor, <italic>h</italic>
			<sub>flr</sub>, were determined using the energy balance equation, <xref ref-type="disp-formula" rid="form0013">Eq. [13]</xref>. Areas and temperatures were determined through measurement, and the supplied thermal energy, <italic>E</italic>
			<sub>gr</sub>, was determined by <xref ref-type="disp-formula" rid="form0001">Eq. [1]</xref>. Thus, the heat transfer coefficients could be determined by regression analysis of <xref ref-type="disp-formula" rid="form0013">Eq. [13]</xref>. The datasets were prepared at hour intervals.</p>
		<graphic id="form0013" xlink:href="sjar_e0202_form13.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<p>where <italic>A</italic>
			<sub>flr</sub> is the floor area, and <italic>t</italic>
			<sub>flr</sub> the floor temperature.</p>
			</sec>
			<sec id="S2.4.3.">
				<title>Modified projected leaf area index (mPLAI)</title>
				<p>The projected leaf area was measured by assuming that it was a circular disc with diameter equal to the average length between the ends of leaves. The projected leaf area in a pot fluctuated from 0.00785 m<sup>2</sup> to 0.0616 m<sup>2</sup> between pinching and blooming as shown in <xref ref-type="fig" rid="F0003">Fig. 3</xref>. As there were 45 days from pinching to blooming, m<italic>PLAI</italic> is expressed using <xref ref-type="disp-formula" rid="form0014">Eq. [14]</xref>.</p>
		<graphic id="form0014" xlink:href="sjar_e0202_form14.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<fig id="F0003">
					<label>Figure 3.</label>
					<caption>
						<title>Views of measurement of the projected leaf area on (a) 0 days, (b) 9 days and (c) 45 days after pinching.</title>
					</caption>
					<graphic xlink:href="sjar_e0202_f03.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
	</fig>
		<p>where <italic>d </italic>is the number of days after pinching, and <italic>n</italic>
			<sub>pot</sub> the number of pots. The arrangement of the pots is shown in <xref ref-type="fig" rid="F0004">Fig. 4</xref>. After 33 days, the leaves of adjacent pots overlapped. Because the projected leaf area is acquired using only the upper leaves, the m<italic>PLAI</italic> did not increase further after 33 days. The number of total test pots for three trays was 1200.</p>
			<fig id="F0004">
					<label>Figure 4.</label>
					<caption>
						<title>Arrangement of roses in pots on a tray.</title>
					</caption>
					<graphic xlink:href="sjar_e0202_f04.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
	</fig>
			</sec>
			<sec id="S2.4.4.">
				<title>SHEF of the plants and the greenhouse floor</title>
				<p>The SHEF coefficients were determined using <xref ref-type="disp-formula" rid="form0015">Eq. [15]</xref> which was established from <xref ref-type="disp-formula" rid="form0005">Eq. [5]</xref>. The energy data of <italic>E</italic>
			<sub>gr</sub>, <italic>E</italic>
			<sub>so</sub> and <italic>E</italic>
			<sub>loss</sub> were collected from Eqs. <xref ref-type="disp-formula" rid="form0001">[1]</xref>, <xref ref-type="disp-formula" rid="form0003">[3]</xref> and <xref ref-type="disp-formula" rid="form0006">[6]</xref>. This analysis was conducted during daytime, and hence, <italic>E</italic>
			<sub>gr</sub> in <xref ref-type="disp-formula" rid="form0015">Eq. [15]</xref> is the amount of recovered energy and not supplied energy. Through regression analysis at intervals of 1°C between 16°C and 25°C, <italic>f</italic>
			<sub>sn-plt</sub> and <italic>f</italic>
			<sub>sn-flr</sub> were obtained.</p>
		<graphic id="form0015" xlink:href="sjar_e0202_form15.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
			</sec>
	</sec>
			<sec id="S2.5.">
				<title>Evaluation of the STE model and analysis of the coefficients</title>
					<p>After the STE model was determined for the test greenhouse, it was evaluated through the error between the measured and estimated amounts of STE and linear regression analysis. Moreover, the STE model includes dynamic coefficients that are changed by time or temperature, and they complicate the calculation of the model. Thus, through fixing these dynamic coefficients, the effects of the coefficients on the model accuracy were investigated.</p>
		<p>A sensitivity analysis on the model coefficients was also conducted. When the coefficients in the model were considered as input and the estimated amounts of STE were considered as output, the effect of the coefficient on the estimation result was assessed. Among several methods for sensitivity analysis of building energy (<xref ref-type="bibr" rid="CIT0022">Lam &amp; Hui, 1996</xref>), a method which is useful for multiple sets of data was chosen, as shown in:</p>
		<graphic id="form0016" xlink:href="sjar_e0202_form16.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<p>where <italic>OP</italic>
			<sub>base</sub> is base output, equal to the estimated value, and <italic>IP</italic>
			<sub>base</sub> is base input, which is equal to the coefficient. <italic>ΔOP</italic> and <italic>ΔIP</italic> are variations of output and input, respectively. High sensitivity coefficients indicate that the model is more sensitive to them and their values must be chosen very carefully.</p>	
			</sec>
			</sec>
			<sec id="S3">
				<title>Results and discussion</title>
				<sec id="S3.1.">
					<title>Coefficients of the STE model for the test greenhouse</title>
					<sec id="S3.1.1.">
						<title>Incidence angle factor for the solar radiation transmissivity</title>
						<p>The incidence angle of the solar radiation changes according to the date and time as shown in <xref ref-type="fig" rid="F0005">Figs. 5a</xref> and <xref ref-type="fig" rid="F0005">5b</xref>. Based on the solar radiation transmissivity changes (<xref ref-type="bibr" rid="CIT0008">Bowman, 1970</xref>), the incidence angle factors were determined as shown in <xref ref-type="fig" rid="F0005">Fig. 5c</xref> and <xref ref-type="fig" rid="F0005">5d</xref> for the wall and the roof, respectively.</p>
						<fig id="F0005">
					<label>Figure 5.</label>
					<caption>
						<title> Incident angles on (a) the wall and (b) the roof for the test greenhouse, and incident angle factors on (c) the wall and (d) the roof for the test greenhouse.</title>
					</caption>
					<graphic xlink:href="sjar_e0202_f05.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
	</fig>
		<p>The dirt/dust factor for the solar radiation transmissivity has been reported as 0.98 for 18 months and 0.95 for 24 months for glass covers (<xref ref-type="bibr" rid="CIT0020">Kim <italic>et al.</italic>, 1997</xref>). The test greenhouse for this research has been operating more than 2 years, so the dirt/dust factor was set as 0.95. Solar radiation transmissivity for the perpendicular beam on the surface is 0.71 for double-layer glass (<xref ref-type="bibr" rid="CIT0018">Hanan, 1998</xref>). Therefore, the solar radiation transmissivity for the test greenhouse is expressed as</p>
		<graphic id="form0017" xlink:href="sjar_e0202_form17.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<p>where the incidence angle factor, <italic>f</italic>
			<sub>ang</sub>, is the dynamic coefficient as shown in <xref ref-type="fig" rid="F0005">Figs. 5c</xref> and <xref ref-type="fig" rid="F0005">5d</xref>.</p>
					</sec>
					<sec id="S3.1.2.">
						<title>Heat transfer coefficients of the test greenhouse</title>
						<p>The overall heat transfer coefficient through covers, <italic>U</italic>
			<sub>cv</sub>, was determined to be 2.98 W/m<sup>2</sup>/K (<italic>p</italic>&lt;0.001), but the floor coefficient was not significant (<italic>p</italic>=0.63). The determined <italic>U</italic>
			<sub>cv</sub> is similar to the coefficient (3 W/m<sup>2</sup>/K) presented by <xref ref-type="bibr" rid="CIT0004">ASAE (1988)</xref> for a double-glass covering. The number of samples for the regression analysis was 25.</p>
					</sec>
					<sec id="S3.1.3.">
						<title>SHEF</title>
								<p>A total of 198 data points of temperature and supplied thermal energy were collected and regression analysis was conducted using <xref ref-type="disp-formula" rid="form0015">Eq. [15]</xref> for every temperature interval. For example, data between 19.5°C and 20.4°C were used for analysis of 20°C. Thus, the number of data for one temperature condition was approximately 20. <xref ref-type="fig" rid="F0006">Figure 6</xref> shows the SHEF according to temperature. The SHEF for the plants and the floor could be expressed by Eqs. <xref ref-type="disp-formula" rid="form0018">[18]</xref> and <xref ref-type="disp-formula" rid="form0019">[19]</xref> with <italic>R</italic>
			<sup>2</sup> of 0.502 and <italic>R</italic>
			<sup>2</sup> of 0.844, respectively.</p>
		<graphic id="form0018" xlink:href="sjar_e0202_form18.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<graphic id="form0019" xlink:href="sjar_e0202_form19.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<fig id="F0006">
					<label>Figure 6.</label>
					<caption>
						<title>Sensible heat emission factor (SHEF) of the plants (■) and the floor (□) according to temperature and their regression lines, with a dashed line for the floor and a solid line for the plants.</title>
					</caption>
					<graphic xlink:href="sjar_e0202_f06.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
	</fig>
		<p>These results show that plants and floor contribute to increase the greenhouse temperature. However, according to temperature increase, the plants retain the SHEF between 0.35 and 0.40, whereas the SHEF of the floor keeps decreasing, which means the floor works as a heat sink at high indoor temperature. In addition, if it is assumed that the floor works as a heat source at low indoor temperature, the result that the SHEF of the floor was maximum at 16°C could be explained. These results provide a hint that greenhouses have to be operated at low temperature to recover the STE effectively.</p>
		<p>Using the SHEF, the relation of sensible and latent heat in the greenhouse indoor air, and the relation of heat transfer between the greenhouse indoor air and plants or floor were simply solved. <xref ref-type="bibr" rid="CIT0021">Joudi &amp; Farhan (2015)</xref> have analyzed the thermal energy between the indoor air and soil in the greenhouse through dividing soil layers into 0.1 m, 0.2 m and 0.5 m depth. Because all these relations depend on the temperature, it is explained that the SHEF depends on the temperature. </p>
					</sec>
				</sec>
				<sec id="S3.2.">
					<title>STE model for the test greenhouse and effects of coefficients on the estimation accuracy</title>
					<p>The coefficients determined for the test greenhouse are listed in <xref ref-type="table" rid="T0002">Table 2</xref>. Measured and estimated amounts of STE were compared as shown in <xref ref-type="fig" rid="F0007">Fig. 7</xref>. The amount of STE decreased in January and sharply increased in February. Monthly errors were evaluated to be 17.9%, 10.4% and 7.4% for December, January and February, respectively. As a result of the linear regression analysis (<xref ref-type="fig" rid="F0008">Fig. 8</xref>), it was found that the STE was under-estimated by 7.2% compared with the measured STE (<xref ref-type="disp-formula" rid="form0020">Eq. [20]</xref>), and the <italic>R</italic>
			<sup>2</sup> value was 0.850. In this study, because the STE data higher than 200 MJ/day were not collected sufficiently, the proposed STE model has an applicable limitation for the high STE condition.</p>
		<graphic id="form0020" xlink:href="sjar_e0202_form20.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
		<p>where <italic>y</italic> and <italic>x</italic> are the STE estimated and measured, respectively.</p>
		<table-wrap id="T0002">
		<label>Table 2.</label>
		<caption>
		<title>Coefficients of the STE model for the test greenhouse.</title>
		</caption>
		<graphic xlink:href="sjar_e0202_t02.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
	</table-wrap>
	<fig id="F0007">
					<label>Figure 7.</label>
					<caption>
						<title> Daily comparison of measured (■) and estimated (■) amounts of surplus thermal energy (STE).</title>
					</caption>
					<graphic xlink:href="sjar_e0202_f07.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
	</fig>
	<fig id="F0008">
					<label>Figure 8.</label>
					<caption>
						<title>Linear regression analysis of measured and estimated surplus thermal energy (STE)</title>
					</caption>
					<graphic xlink:href="sjar_e0202_f08.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
	</fig>
		<p>As shown in <xref ref-type="table" rid="T0002">Table 2</xref>, the incidence angle factor (<italic>f</italic>
			<sub>ang</sub>), the SHEFs (<italic>f</italic>
			<sub>sn-plt</sub> and <italic>f</italic>
			<sub>sn-flr</sub>) and <italic>mPLAI</italic> are time or temperature dependent. We investigated the effects of these coefficients on the estimation accuracy of the STE model. Because the incidence angle factor is generally one during the time period that STE exists, the model was re-evaluated with a fixed incidence angle factor of 1. In addition, the model was re-evaluated with fixing of the SHEFs as the values at 25ºC, 26ºC and 27ºC, respectively. The temperature set-point for recovering STE was 26ºC. The <italic>mPLAI</italic> was fixed as 0, 0.575 and 1 for ignoring plants, full of plants and ignoring floor, respectively.</p>
		<p><xref ref-type="fig" rid="F0009">Figure 9</xref> shows the monthly errors according to fixing the coefficients. When the incidence angle factor was fixed at 1, the SHEFs were fixed at 26ºC (SHEF at 26ºC), and plants grew at the normal plant density (m<italic>PLAI</italic>=0.575). The monthly errors were slightly changed compared with the errors when the all coefficients were not fixed (No fixed). Moreover, even though these three coefficients were fixed at the same time (All fixing), the errors were not seriously increased. However, when the SHEFs were fixed at 25ºC or 27ºC, and the m<italic>PLAI</italic> was fixed as 0 or 1, the errors seriously increased.</p>
		<fig id="F0009">
					<label>Figure 9.</label>
					<caption>
						<title>Monthly error of the STE model with fixed coefficients in December (□), January (■) and February (■).</title>
					</caption>
					<graphic xlink:href="sjar_e0202_f09.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
	</fig>
		<p>Similar results were obtained through the linear regression analysis (<xref ref-type="fig" rid="F0010">Fig. 10</xref>). The over/under-estimation ratios and the <italic>R</italic>
			<sup>2</sup> values were sensitively changed because of the SHEFs and the m<italic>PLAI</italic>. Consequently, it was revealed that the error of the STE model mainly relies on these two coefficients.</p>
			<fig id="F0010">
					<label>Figure 10.</label>
					<caption>
						<title>Evaluation of linear regression analysis of the STE model and fixed coefficients; (a) over/under estimation ratios calculated by the slope and (b) <italic>R</italic>
			<sup>2</sup> values of acquired linear equations.</title>
					</caption>
					<graphic xlink:href="sjar_e0202_f10.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
	</fig>
				</sec>
				<sec id="S3.3.">
					<title>Sensitivity analysis of the STE model</title>
					<p>The results of the sensitivity analysis of the STE model are shown in <xref ref-type="fig" rid="F0011">Fig. 11</xref>. In January, the STE model was mostly sensitive to all coefficients, and this might be attributed to the small amount of STE. Small changes in STE result in a significant increase of the sensitivity coefficient. For the m<italic>PLAI</italic> and the SHEFs, the sensitivity was stable for coefficient changes. However, as the sensitivity of the STE model was highly influenced by the solar radiation transmissivity and the overall heat transfer coefficient in January, these coefficients must be carefully determined. This result also means that improvement of the solar radiation transmissivity and the heat loss through the greenhouse cover is vital to recovering more STE. As simple ways to achieve this, cleaning the greenhouse covers, which improves the solar radiation transmissivity, has been suggested (<xref ref-type="bibr" rid="CIT0015">Geoola <italic>et al.</italic>, 1998</xref>), and reinforcing sealing such repairing tears in covers and preventing the leakage may be helpful. Cleaning the covers also increases the photosynthetic rate of crops, and reinforcing sealing is necessary to save heating energy.</p>
					<fig id="F0011">
					<label>Figure 11.</label>
					<caption>
						<title>Sensitivity analysis of the STE model on (a) light transmissivity; (b) m<italic>PLAI</italic>; (c) overall heat transfer coefficient; (d) SHEF of the plant; and (e) SHEF of the floor in December (◊), January (■) and February (Δ).</title>
					</caption>
					<graphic xlink:href="sjar_e0202_f11.jpg" xmlns:xlink="http://www.w3.org/1999/xlink"/>
	</fig>
		<p>As conclusions, this study was conducted to propose a model to estimate the surplus thermal energy (STE). Energy balance equations were basically used, and the sensible heat emission factor (SHEF) from plants and floor was newly introduced to develop the STE model. Monthly errors of the model were evaluated to be 17.9%, 10.4% and 7.4% for December, January and February, respectively. The STE model shows that the solar radiation transmissivity and the overall heat transfer coefficient of greenhouse covers are sensitively influenced to the amount of STE. Because this model was developed and verified through a small glass greenhouse, it must be tested in a larger greenhouse. As future research, it is necessary to find the coefficients in the STE model for different conditions of greenhouses.</p>
				</sec>
			</sec>
	</body>
	<back>
	<ref-list id="S4">
	<title>References</title>
	<ref id="CIT0001">
	<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Abdel-Ghany</surname>
				<given-names>AM</given-names>
			</name>
			<name>
				<surname>Al-Helal</surname>
				<given-names>IM</given-names>
			</name>
			</person-group>
			<article-title>Solar energy utilization by a greenhouse: general relations</article-title>
			<source>Renew Energ</source>
			<year>2011</year>
			<volume>36</volume>
			<issue>1</issue>
			<fpage>189</fpage>
			<lpage>196</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.renene.2010.06.020">http://dx.doi.org/10.1016/j.renene.2010.06.020</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0002">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Ahmed</surname>
				<given-names>MA</given-names>
			</name>
			<name>
				<surname>Ahmad</surname>
				<given-names>F</given-names>
			</name>
			<name>
				<surname>Akhtar</surname>
				<given-names>MW</given-names>
			</name>
			</person-group>
			<article-title>Estimation of global and diffuse solar radiation for hyderabad, Sindh, Pakistan</article-title>
			<source>J Basic Appl Sci</source>
			<year>2009</year>
			<volume>5</volume>
			<issue>2</issue>
			<fpage>73</fpage>
			<lpage>77</lpage>
			</element-citation>
			</ref>
		<ref id="CIT0003">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Al-Mohamad</surname>
				<given-names>A</given-names>
			</name>
			</person-group>
			<article-title>Global, direct and diffuse solar-radiation in Syria</article-title>
			<source>Appl Energ</source>
			<year>2004</year>
			<volume>79</volume>
			<issue>2</issue>
			<fpage>191</fpage>
			<lpage>200</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.apenergy.2003.12.011">http://dx.doi.org/10.1016/j.apenergy.2003.12.01</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0004">
		<element-citation publication-type="book">
			<collab>ASAE</collab>
			<person-group person-group-type="editor">
			<name>
				<surname>Hahn</surname>
				<given-names>RH</given-names>
			</name>
			<name>
				<surname>Rosentreter</surname>
				<given-names>EE</given-names>
			</name>
			</person-group>
			<source>ASAE Engineering Practice. Heating, ventilating and cooling greenhouses</source>
			<year>1988</year>
			<edition>35</edition>
			<publisher-name>ASAE</publisher-name>
			<publisher-loc>St. Joseph</publisher-loc>
			</element-citation>
			</ref>
		<ref id="CIT0005">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Bakker</surname>
				<given-names>JC</given-names>
			</name>
			<name>
				<surname>de Zwart</surname>
				<given-names>HF</given-names>
			</name>
			<name>
				<surname>Campen</surname>
				<given-names>JB</given-names>
			</name>
			</person-group>
			<article-title>Greenhouse cooling and heat recovery using fine wire heat exchangers in a closed pot plant greenhouse: design of an energy producing greenhouse</article-title>
			<source>Acta Hortic</source>
			<year>2006</year>
			<volume>719</volume>
			<fpage>263</fpage>
			<lpage>270</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.17660/ActaHortic.2006.719.29"></ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0006">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Barclay</surname>
				<given-names>HJ</given-names>
			</name>
			</person-group>
			<article-title>Conversion of total leaf area to projected leaf area in lodgepole pine and Douglas-fir</article-title>
			<source>Tree Physiol</source>
			<year>1998</year>
			<volume>18</volume>
			<fpage>185</fpage>
			<lpage>193</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1093/treephys/18.3.185">http://dx.doi.org/10.1093/treephys/18.3.185</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0007">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Benli</surname>
				<given-names>H</given-names>
			</name>
			<name>
				<surname>Durmuş</surname>
				<given-names>A</given-names>
			</name>
			</person-group>
			<article-title>Performance analysis of a latent heat storage system with phase change material for new designed solar collectors in greenhouse heating</article-title>
			<source>Sol Energy</source>
			<year>2009</year>
			<volume>83</volume>
			<issue>12</issue>
			<fpage>2109</fpage>
			<lpage>2119</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.solener.2009.07.005">http://dx.doi.org/10.1016/j.solener.2009.07.005</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0008">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Bowman</surname>
				<given-names>GE</given-names>
			</name>
			</person-group>
			<article-title>The transmission of diffuse light by a sloping roof</article-title>
			<source>J Agr Eng Res</source>
			<year>1970</year>
			<volume>15</volume>
			<issue>2</issue>
			<fpage>100</fpage>
			<lpage>105</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/0021-8634(70)90081-8">http://dx.doi.org/10.1016/0021-8634(70)90081-8</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0009">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Cabrera</surname>
				<given-names>FJ</given-names>
			</name>
			<name>
				<surname>Baille</surname>
				<given-names>A</given-names>
			</name>
			<name>
				<surname>López</surname>
				<given-names>JC</given-names>
			</name>
			<name>
				<surname>González-Real</surname>
				<given-names>MM</given-names>
			</name>
			<name>
				<surname>Pérez-Parra</surname>
				<given-names>J</given-names>
			</name>
			</person-group>
			<article-title>Effects of cover diffusive properties on the components of greenhouse solar radiation</article-title>
			<source>Biosyst Eng</source>
			<year>2009</year>
			<volume>103</volume>
			<issue>3</issue>
			<fpage>344</fpage>
			<lpage>356</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.biosystemseng.2009.03.008">http://dx.doi.org/10.1016/j.biosystemseng.2009.03.008</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0010">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Chou</surname>
				<given-names>SK</given-names>
			</name>
			<name>
				<surname>Chua</surname>
				<given-names>KJ</given-names>
			</name>
			<name>
				<surname>Ho</surname>
				<given-names>JC</given-names>
			</name>
			<name>
				<surname>Ooi</surname>
				<given-names>CL</given-names>
			</name>
			</person-group>
			<article-title>On the study of an energy-efficient greenhouse for heating, cooling and dehumidification applications</article-title>
			<source>Appl Energ</source>
			<year>2004</year>
			<volume>77</volume>
			<issue>4</issue>
			<fpage>355</fpage>
			<lpage>373</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/S0306-2619(03)00157-0">http://dx.doi.org/10.1016/S0306-2619(03)00157-0</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0011">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Critten</surname>
				<given-names>DL</given-names>
			</name>
			</person-group>
			<article-title>Light transmission losses due to structural members in multispan greenhouses under diffuse skylight conditions</article-title>
			<source>J Agr Eng Res</source>
			<year>1987</year>
			<volume>38</volume>
			<issue>3</issue>
			<fpage>193</fpage>
			<lpage>207</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/0021-8634(87)90080-1">http://dx.doi.org/10.1016/0021-8634(87)90080-1</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0012">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Fabrizio</surname>
				<given-names>E</given-names>
			</name>
			</person-group>
			<article-title>Energy reduction measures in agricultural greenhouses heating: envelope, systems and solar energy collection</article-title>
			<source>Energ Buildings</source>
			<year>2012</year>
			<volume>53</volume>
			<fpage>57</fpage>
			<lpage>63</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.enbuild.2012.07.003">http://dx.doi.org/10.1016/j.enbuild.2012.07.003</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0013">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Ferreira</surname>
				<given-names>PM</given-names>
			</name>
			<name>
				<surname>Faria</surname>
				<given-names>EA</given-names>
			</name>
			<name>
				<surname>Ruano</surname>
				<given-names>AE</given-names>
			</name>
			</person-group>
			<article-title>Neural network models in greenhouse air temperature prediction</article-title>
			<source>Neurocomputing</source>
			<year>2002</year>
			<volume>43</volume>
			<issue>1–4</issue>
			<fpage>51</fpage>
			<lpage>75</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/S0925-2312(01)00620-8">http://dx.doi.org/10.1016/S0925-2312(01)00620-8</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0014">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Gauthier</surname>
				<given-names>C</given-names>
			</name>
			<name>
				<surname>Lacroix</surname>
				<given-names>M</given-names>
			</name>
			<name>
				<surname>Bernier</surname>
				<given-names>H</given-names>
			</name>
			</person-group>
			<article-title>Numerical simulation of soil heat exchanger-storage systems for greenhouses</article-title>
			<source>Sol Energy</source>
			<year>1997</year>
			<volume>60</volume>
			<issue>6</issue>
			<fpage>333</fpage>
			<lpage>346</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/S0038-092X(97)00022-4">http://dx.doi.org/10.1016/S0038-092X(97)00022-4</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0015">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Geoola</surname>
				<given-names>F</given-names>
			</name>
			<name>
				<surname>Kashti</surname>
				<given-names>Y</given-names>
			</name>
			<name>
				<surname>Peiper</surname>
				<given-names>UM</given-names>
			</name>
			</person-group>
			<article-title>A model greenhouse for testing the role of condensation, dust and dirt on the solar radiation transmissivity of greenhouse cladding materials</article-title>
			<source>J Agr Eng Res</source>
			<year>1998</year>
			<volume>71</volume>
			<issue>4</issue>
			<fpage>339</fpage>
			<lpage>346</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1006/jaer.1998.0333">http://dx.doi.org/10.1006/jaer.1998.0333</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0016">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Hamdan</surname>
				<given-names>MA</given-names>
			</name>
			<name>
				<surname>Al-Sayeh</surname>
				<given-names>AI</given-names>
			</name>
			<name>
				<surname>Jubran</surname>
				<given-names>BA</given-names>
			</name>
			</person-group>
			<article-title>Solar hybrid heating systems for greenhouses</article-title>
			<source>Appl Energ</source>
			<year>1992</year>
			<volume>41</volume>
			<issue>4</issue>
			<fpage>251</fpage>
			<lpage>260</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/0306-2619(92)90006-W">http://dx.doi.org/10.1016/0306-2619(92)90006-W</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0017">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Han</surname>
				<given-names>JH</given-names>
			</name>
			<name>
				<surname>Kwon</surname>
				<given-names>HJ</given-names>
			</name>
			<name>
				<surname>Yoon</surname>
				<given-names>JY</given-names>
			</name>
			<name>
				<surname>Kim</surname>
				<given-names>K</given-names>
			</name>
			<name>
				<surname>Nam</surname>
				<given-names>SW</given-names>
			</name>
			<name>
				<surname>Son</surname>
				<given-names>JE</given-names>
			</name>
			</person-group>
			<article-title>Analysis of the thermal environment in a mushroom house using sensible heat balance and 3-D computational fluid dynamics</article-title>
			<source>Biosyst Eng</source>
			<year>2009</year>
			<volume>104</volume>
			<issue>3</issue>
			<fpage>417</fpage>
			<lpage>424</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.biosystemseng.2009.07.007">http://dx.doi.org/10.1016/j.biosystemseng.2009.07.007</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0018">
		<element-citation publication-type="book">
			<person-group person-group-type="author">
			<name>
				<surname>Hanan</surname>
				<given-names>JJ</given-names>
			</name>
			</person-group>
			<source>Greenhouses advanced technology for protected horticulture</source>
			<year>1998</year>
			<publisher-name>CRC Press</publisher-name>
			<publisher-loc>New York</publisher-loc>
			</element-citation>
			</ref>
		<ref id="CIT0019">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Hepbasli</surname>
				<given-names>A</given-names>
			</name>
			</person-group>
			<article-title>A comparative investigation of various greenhouse heating options using exergy analysis method</article-title>
			<source>Appl Energ</source>
			<year>2011</year>
			<volume>88</volume>
			<issue>12</issue>
			<fpage>4411</fpage>
			<lpage>4423</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.apenergy.2011.05.022">http://dx.doi.org/10.1016/j.apenergy.2011.05.022</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0020">
		<element-citation publication-type="book">
			<person-group person-group-type="author">
			<name>
				<surname>Kim</surname>
				<given-names>MK</given-names>
			</name>
			<name>
				<surname>Lee</surname>
				<given-names>CG</given-names>
			</name>
			<name>
				<surname>Jung</surname>
				<given-names>SJ</given-names>
			</name>
			<name>
				<surname>Ryou</surname>
				<given-names>KH</given-names>
			</name>
			<name>
				<surname>Suh</surname>
				<given-names>WM</given-names>
			</name>
			<name>
				<surname>Yoon</surname>
				<given-names>YC</given-names>
			</name>
			<name>
				<surname>Son</surname>
				<given-names>JE</given-names>
			</name>
			<name>
				<surname>Lee</surname>
				<given-names>HW</given-names>
			</name>
			<name>
				<surname>Nam</surname>
				<given-names>SW</given-names>
			</name>
			<name>
				<surname>Cho</surname>
				<given-names>SM</given-names>
			</name>
			</person-group>
			<source>Design standards for greenhouse environment</source>
			<year>1997</year>
			<publisher-name>Korea Rural Community Corporation</publisher-name>
			<comment>In Korean</comment>
			</element-citation>
			</ref>
		<ref id="CIT0021">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Joudi</surname>
				<given-names>KA</given-names>
			</name>
			<name>
				<surname>Farhan</surname>
				<given-names>AA</given-names>
			</name>
			</person-group>
			<article-title>A dynamic model and an experimental study for the internal air and soil temperatures in an innovative greenhouse</article-title>
			<source>Energ Convers Manage</source>
			<year>2015</year>
			<volume>91</volume>
			<fpage>76</fpage>
			<lpage>82</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.enconman.2014.11.052">http://dx.doi.org/10.1016/j.enconman.2014.11.052</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0022">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Lam</surname>
				<given-names>JC</given-names>
			</name>
			<name>
				<surname>Hui</surname>
				<given-names>SCM</given-names>
			</name>
			</person-group>
			<article-title>Sensitivity analysis of energy performance of office buildings</article-title>
			<source>Build Environ</source>
			<year>1996</year>
			<volume>31</volume>
			<issue>1</issue>
			<fpage>27</fpage>
			<lpage>39</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/0360-1323(95)00031-3">http://dx.doi.org/10.1016/0360-1323(95)00031-3</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0023">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Lee</surname>
				<given-names>SH</given-names>
			</name>
			<name>
				<surname>Ryou</surname>
				<given-names>YS</given-names>
			</name>
			<name>
				<surname>Moon</surname>
				<given-names>JP</given-names>
			</name>
			<name>
				<surname>Yun</surname>
				<given-names>NK</given-names>
			</name>
			<name>
				<surname>Kwon</surname>
				<given-names>JK</given-names>
			</name>
			<name>
				<surname>Lee</surname>
				<given-names>SJ</given-names>
			</name>
			<name>
				<surname>Kim</surname>
				<given-names>KW</given-names>
			</name>
			</person-group>
			<article-title>Solar energy storage effectiveness on double layered single span plastic greenhouse</article-title>
			<source>J Biosyst Eng</source>
			<year>2011</year>
			<volume>36</volume>
			<issue>3</issue>
			<fpage>217</fpage>
			<lpage>222</lpage>
			<comment>In Korean</comment>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.5307/JBE.2011.36.3.217">http://dx.doi.org/10.5307/JBE.2011.36.3.217</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0024">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Leonidopoulos</surname>
				<given-names>G</given-names>
			</name>
			</person-group>
			<article-title>Greenhouse daily sun-radiation intensity variation, daily temperature variation and heat profits through the polymeric cover</article-title>
			<source>Polym Test</source>
			<year>2000</year>
			<volume>19</volume>
			<issue>7</issue>
			<fpage>813</fpage>
			<lpage>820</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/S0142-9418(99)00051-3">http://dx.doi.org/10.1016/S0142-9418(99)00051-3</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0025">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Li</surname>
				<given-names>S</given-names>
			</name>
			<name>
				<surname>Kurata</surname>
				<given-names>K</given-names>
			</name>
			<name>
				<surname>Takakura</surname>
				<given-names>T</given-names>
			</name>
			</person-group>
			<article-title>Direct solar radiation penetration into row crop canopies in a lean-to greenhouse</article-title>
			<source>Agr Forest Meteorol</source>
			<year>2000</year>
			<volume>100</volume>
			<issue>2-3</issue>
			<fpage>243</fpage>
			<lpage>253</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/S0168-1923(99)00044-1">http://dx.doi.org/10.1016/S0168-1923(99)00044-1</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0026">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Najjar</surname>
				<given-names>A</given-names>
			</name>
			<name>
				<surname>Hasan</surname>
				<given-names>A</given-names>
			</name>
			</person-group>
			<article-title>Modeling of greenhouse with PCM energy storage</article-title>
			<source>Energ Convers Manage</source>
			<year>2008</year>
			<volume>49</volume>
			<issue>11</issue>
			<fpage>3338</fpage>
			<lpage>3342</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.enconman.2008.04.015">http://dx.doi.org/10.1016/j.enconman.2008.04.015</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0027">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Ntinas</surname>
				<given-names>GK</given-names>
			</name>
			<name>
				<surname>Fragos</surname>
				<given-names>VP</given-names>
			</name>
			<name>
				<surname>Nikita-Martzopoulou</surname>
				<given-names>CH</given-names>
			</name>
			</person-group>
			<article-title>Thermal analysis of a hybrid solar energy saving system inside a greenhouse</article-title>
			<source>Energ Convers Manage</source>
			<year>2014</year>
			<volume>81</volume>
			<fpage>428</fpage>
			<lpage>439</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.enconman.2014.02.058">http://dx.doi.org/10.1016/j.enconman.2014.02.058</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0028">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Ozgener</surname>
				<given-names>O</given-names>
			</name>
			<name>
				<surname>Hepbasli</surname>
				<given-names>A</given-names>
			</name>
			</person-group>
			<article-title>Experimental performance analysis of a solar assisted ground-source heat pump greenhouse heating system</article-title>
			<source>Energ Buildings</source>
			<year>2005</year>
			<volume>37</volume>
			<issue>1</issue>
			<fpage>101</fpage>
			<lpage>110</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.enbuild.2004.06.003">http://dx.doi.org/10.1016/j.enbuild.2004.06.003</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0029">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Papadakis</surname>
				<given-names>G</given-names>
			</name>
			<name>
				<surname>Manolakos</surname>
				<given-names>D</given-names>
			</name>
			<name>
				<surname>Kyritsis</surname>
				<given-names>S</given-names>
			</name>
			</person-group>
			<article-title>Solar radiation transmissivity of a single-span greenhouse through measurements on scale models</article-title>
			<source>J Agr Eng Res</source>
			<year>1998</year>
			<volume>71</volume>
			<issue>4</issue>
			<fpage>331</fpage>
			<lpage>338</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1006/jaer.1998.0331">http://dx.doi.org/10.1006/jaer.1998.0331</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0030">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Pavlou</surname>
				<given-names>G</given-names>
			</name>
			</person-group>
			<article-title>Evaluation of thermal performance of water-filled polyethylene tubes used for passive solar greenhouse heating</article-title>
			<source>Acta Hortic</source>
			<year>1991</year>
			<volume>287</volume>
			<fpage>89</fpage>
			<lpage>98</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.17660/ActaHortic.1991.287.8">http://dx.doi.org/10.17660/ActaHortic.1991.287.8</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0031">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Sethi</surname>
				<given-names>VP</given-names>
			</name>
			</person-group>
			<article-title>On the selection of shape and orientation of a greenhouse: Thermal modeling and experimental validation</article-title>
			<source>Sol Energy</source>
			<year>2009</year>
			<volume>83</volume>
			<issue>1</issue>
			<fpage>21</fpage>
			<lpage>38</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.solener.2008.05.018">http://dx.doi.org/10.1016/j.solener.2008.05.018</ext-link></comment>
			</element-citation>
</ref>
		<ref id="CIT0032">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Sethi</surname>
				<given-names>VP</given-names>
			</name>
			<name>
				<surname>Sharma</surname>
				<given-names>SK</given-names>
			</name>
			</person-group>
			<article-title>Survey and evaluation of heating technologies for worldwide agricultural greenhouse applications</article-title>
			<source>Sol Energy</source>
			<year>2008</year>
			<volume>82</volume>
			<issue>9</issue>
			<fpage>832</fpage>
			<lpage>859</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.solener.2008.02.010">http://dx.doi.org/10.1016/j.solener.2008.02.010</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0033">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Sharma</surname>
				<given-names>PK</given-names>
			</name>
			<name>
				<surname>Tiwari</surname>
				<given-names>GN</given-names>
			</name>
			<name>
				<surname>Sorayan</surname>
				<given-names>VPS</given-names>
			</name>
			</person-group>
			<article-title>Temperature distribution in different zones of the micro-climate of a greenhouse: A dynamic model</article-title>
			<source>Energ Convers Manage</source>
			<year>1999</year>
			<volume>40</volume>
			<issue>3</issue>
			<fpage>335</fpage>
			<lpage>348</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/S0196-8904(98)00100-9">http://dx.doi.org/10.1016/S0196-8904(98)00100-9</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0034">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Shukla</surname>
				<given-names>A</given-names>
			</name>
			<name>
				<surname>Tiwari</surname>
				<given-names>GN</given-names>
			</name>
			<name>
				<surname>Sodha</surname>
				<given-names>MS</given-names>
			</name>
			</person-group>
			<article-title>Thermal modeling for greenhouse heating by using thermal curtain and an earth–air heat exchanger</article-title>
			<source>Build Environ</source>
			<year>2006</year>
			<volume>41</volume>
			<fpage>843</fpage>
			<lpage>850</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.buildenv.2005.04.014">http://dx.doi.org/10.1016/j.buildenv.2005.04.014</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0035">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Suh</surname>
				<given-names>WM</given-names>
			</name>
			<name>
				<surname>Bae</surname>
				<given-names>YH</given-names>
			</name>
			<name>
				<surname>Ryou</surname>
				<given-names>YS</given-names>
			</name>
			<name>
				<surname>Lee</surname>
				<given-names>SH</given-names>
			</name>
			<name>
				<surname>Yoon</surname>
				<given-names>YC</given-names>
			</name>
			</person-group>
			<article-title>Estimation of surplus solar energy in greenhouse (I) - Case study based on 1-2W type</article-title>
			<source>J Korean Soc Agr Engineers</source>
			<year>2009</year>
			<volume>51</volume>
			<issue>5</issue>
			<fpage>79</fpage>
			<lpage>86</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.5389/KSAE.2009.51.5.079">http://dx.doi.org/10.5389/KSAE.2009.51.5.079</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0036">
		<element-citation publication-type="book">
			<person-group person-group-type="author">
			<name>
				<surname>Taiz</surname>
				<given-names>L</given-names>
			</name>
			<name>
				<surname>Zeiger</surname>
				<given-names>E</given-names>
			</name>
			</person-group>
			<source>Plant physiology</source>
			<year>1991</year>
			<publisher-name>The Benjamin/Cummings Publ. Co.</publisher-name>
			<publisher-loc>Redwood City, CA, USA</publisher-loc>
			</element-citation>
			</ref>
		<ref id="CIT0037">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Vadiee</surname>
				<given-names>A</given-names>
			</name>
			<name>
				<surname>Martin</surname>
				<given-names>V</given-names>
			</name>
			</person-group>
			<article-title>Energy management in horticultural applications through the closed greenhouse concept, state of the art</article-title>
			<source>Renew Sust Energ Rev</source>
			<year>2012</year>
			<volume>16</volume>
			<issue>7</issue>
			<fpage>5087</fpage>
			<lpage>5100</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.rser.2012.04.022">http://dx.doi.org/10.1016/j.rser.2012.04.022</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0038">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Vadiee</surname>
				<given-names>A</given-names>
			</name>
			<name>
				<surname>Martin</surname>
				<given-names>V</given-names>
			</name>
			</person-group>
			<article-title>Energy analysis and thermoeconomic assessment of the closed greenhouse – The largest commercial solar building</article-title>
			<source>Appl Energ</source>
			<year>2013</year>
			<volume>102</volume>
			<fpage>1256</fpage>
			<lpage>1266</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.apenergy.2012.06.051">http://dx.doi.org/10.1016/j.apenergy.2012.06.051</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0039">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Vadiee</surname>
				<given-names>A</given-names>
			</name>
			<name>
				<surname>Martin</surname>
				<given-names>V</given-names>
			</name>
			</person-group>
			<article-title>Thermal energy storage strategies for effective closed greenhouse design</article-title>
			<source>Appl Energ</source>
			<year>2013</year>
			<volume>109</volume>
			<fpage>337</fpage>
			<lpage>343</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.apenergy.2012.12.065">http://dx.doi.org/10.1016/j.apenergy.2012.12.065</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0040">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Yang</surname>
				<given-names>SH</given-names>
			</name>
			<name>
				<surname>Rhee</surname>
				<given-names>JY</given-names>
			</name>
			</person-group>
			<article-title>Utilization and performance evaluation of a surplus air heat pump system for greenhouse cooling and heating</article-title>
			<source>Appl Energ</source>
			<year>2013</year>
			<volume>105</volume>
			<fpage>244</fpage>
			<lpage>251</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.1016/j.apenergy.2012.12.038">http://dx.doi.org/10.1016/j.apenergy.2012.12.038</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0041">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Yang</surname>
				<given-names>SH</given-names>
			</name>
			<name>
				<surname>Lee</surname>
				<given-names>CG</given-names>
			</name>
			<name>
				<surname>Lee</surname>
				<given-names>WK</given-names>
			</name>
			<name>
				<surname>Ashtiani</surname>
				<given-names>AA</given-names>
			</name>
			<name>
				<surname>Kim</surname>
				<given-names>JY</given-names>
			</name>
			<name>
				<surname>Lee</surname>
				<given-names>SD</given-names>
			</name>
			<name>
				<surname>Rhee</surname>
				<given-names>JY</given-names>
			</name>
			</person-group>
			<article-title>Heating and cooling system for utilization of surplus air thermal energy in greenhouse and its control logic</article-title>
			<source>J Biosyst Eng</source>
			<year>2012</year>
			<volume>37</volume>
			<issue>1</issue>
			<fpage>19</fpage>
			<lpage>27</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.5307/JBE.2012.37.1.019">http://dx.doi.org/10.5307/JBE.2012.37.1.019</ext-link></comment>
			</element-citation>
			</ref>
		<ref id="CIT0042">
		<element-citation publication-type="journal">
			<person-group person-group-type="author">
			<name>
				<surname>Yang</surname>
				<given-names>SH</given-names>
			</name>
			<name>
				<surname>Lee</surname>
				<given-names>CG</given-names>
			</name>
			<name>
				<surname>Kim</surname>
				<given-names>JY</given-names>
			</name>
			<name>
				<surname>Lee</surname>
				<given-names>WK</given-names>
			</name>
			<name>
				<surname>Ashtiani</surname>
				<given-names>AA</given-names>
			</name>
			<name>
				<surname>Rhee</surname>
				<given-names>JY</given-names>
			</name>
			</person-group>
			<article-title>Effects of fan-aspirated radiation shield for temperature measurement in greenhouse environment</article-title>
			<source>J Biosyst Eng</source>
			<year>2012</year>
			<volume>37</volume>
			<issue>4</issue>
			<fpage>245</fpage>
			<lpage>251</lpage>
			<comment><ext-link ext-link-type="uri" xlink:href="http://dx.doi.org/10.5307/JBE.2012.37.4.245">http://dx.doi.org/10.5307/JBE.2012.37.4.245</ext-link></comment>
			</element-citation>
			</ref>
	</ref-list>
	</back>
</article>