Experimental results and modelling of humidity control strategies for greenhouses in continental and coastal settings in the Mediterranean region. I: Experimental results and model development
Abstract
Experimental strategies for controlling humidity were compared in a greenhouse sited in Madrid, a continental site
in the Mediterranean region. Small roof window apertures significantly reduced the relative humidity with only a
limited increase in associated energy consumption. A simplified climate model with four energy exchange terms
(heating, insolation, losses through structure, and losses through windows) and three mass exchange terms
(evapotranspiration, losses through structure, and losses through windows) was validated, allowing relative humidity
to be predicted with an error of < 9%.
Downloads
© CSIC. Manuscripts published in both the print and online versions of this journal are the property of the Consejo Superior de Investigaciones Científicas, and quoting this source is a requirement for any partial or full reproduction.
All contents of this electronic edition, except where otherwise noted, are distributed under a Creative Commons Attribution 4.0 International (CC BY 4.0) licence. You may read the basic information and the legal text of the licence. The indication of the CC BY 4.0 licence must be expressly stated in this way when necessary.