Development of a model to calculate the overall heat transfer coefficient of greenhouse covers
Abstract
A Building Energy Simulation (BES) model based on TRNSYS, was developed to investigate the overall heat transfer coefficient (U-value) of greenhouse covers including polyethylene (PE), polycarbonate (PC), polyvinyl chloride (PVC), and horticultural glass (HG). This was used to determine the influences of inside-to-outside temperature difference, wind speed, and night sky radiation on the U-values of these materials. The model was calibrated using published values of the inside and outside convective heat transfer coefficients. Validation of the model was demonstrated by the agreement between the computed and experimental results for a single-layer PE film. The results from the BES model showed significant changes in U-value in response to variations in weather parameters and the use of single or double layer greenhouse covers. It was found that the U-value of PC, PVC, and HG was 9%, 4%, and 15% lower, respectively, than that for PE. In addition, by using double glazing a 34% reduction in heat loss was noted. For the given temperature U-value increases as wind speed increases. The slopes at the temperature differences of 20, 30, 40, and 50 °C, were approximately 0.3, 0.5, 0.7, and 0.9, respectively. The results agree with those put forward by other researchers. Hence, the presented model is reliable and can play a valuable role in future work on greenhouse energy modelling.
Downloads
References
Abu Bakar NN, Hassan MY, Abdullah H, Rahman HA, Abdullah MP, Hussin F, Bandi M, 2015. Energy efficiency index as an indicator for measuring building energy performance: A review. Renew Sust Energ Rev 44: 1-11. https://doi.org/10.1016/j.rser.2014.12.018
Al-Mahdouri A, Baneshi M, Gonome H, Okajima J, Maruyama S, 2013. Evaluation of optical properties and thermal performances of different greenhouse covering materials. Solar Energy 96: 21-32. https://doi.org/10.1016/j.solener.2013.06.029
Asdrubali F, Baldinelli G, 2011. Thermal transmittance measurements with the hot box method: Calibration, experimental procedures, and uncertainty analyses of three different approaches. Energ Build 43: 1618-1626. https://doi.org/10.1016/j.enbuild.2011.03.005
ASTM, 1993. Standard test method for steady-state thermal performance of building assemblies by means of a guarded hot box. ASTM standards C236-89: 52-62.
Baille A, López JC, Bonachela S, González-Real MM, Montero JI, 2006. Night energy balance in a heated low-cost plastic greenhouse. Agr Forest Meteorol 137: 107-118. https://doi.org/10.1016/j.agrformet.2006.03.008
Buratti C, Belloni E, Lunghi L, Barbanera M, 2016. Thermal conductivity measurements by means of a new 'small hot-box'apparatus: Manufacturing, calibration and preliminary experimental tests on different materials. Int J Thermophys 37: 47. https://doi.org/10.1007/s10765-016-2052-2
Calleja Rodríguez G, Carrillo Andrés A, Domínguez Muñoz F, Cejudo López JM, Zhang Y, 2013. Uncertainties and sensitivity analysis in building energy simulation using macroparameters. Energ Build 67: 79-87. https://doi.org/10.1016/j.enbuild.2013.08.009
Diop S, Lee JW, Na WH, Lee HW, 2012. Overall heat transfer coefficient measurement of covering materials with thermal screens for greenhouse using the hot box method. J Kor Soc Agr Eng 54: 1-7. https://doi.org/10.5389/KSAE.2012.54.5.001
Diop S, Lee JW, Lee HW, 2014. Measurement and comparison of overall heat transfer coefficients for greenhouse covering materials with thermal screens. J Kor Soc Agr Eng 56: 41-51. https://doi.org/10.5389/KSAE.2014.56.4.041
Emmel MG, Abadie MO, Mendes N, 2007. New external convective heat transfer coefficient correlations for isolated low-rise buildings. Energ Build 39: 335-342. https://doi.org/10.1016/j.enbuild.2006.08.001
Esen M, Yuksel T, 2013. Experimental evaluation of using various renewable energy sources for heating a greenhouse. Energ Build 65: 340-351. https://doi.org/10.1016/j.enbuild.2013.06.018
Fadel MA, Hammad BAB, Alhosany F, Iwaimer O, 2016. Greenhouses covering materials: A comparative study. Agr Eng Int: CIGR J 18: 48-57.
Feuilloley P, Issanchou G, 1996. Greenhouse covering materials measurement and modelling of thermal properties using the hot box method, and condensation effects. J Agric Eng Res 65: 129-142. https://doi.org/10.1006/jaer.1996.0085
Gao Y, Roux JJ, Teodosiu C, Zhao LH, 2004. Reduced linear state model of hollow blocks walls, validation using hot box measurements. Energ Build 36: 1107-1115. https://doi.org/10.1016/j.enbuild.2004.03.008
Garzoli K, Blackwell J, 1981. An analysis of the nocturnal heat loss from a single skin plastic greenhouse. J Agric Eng Res 26: 203-214. https://doi.org/10.1016/0021-8634(81)90105-0
Geoola F, Kashti Y, Levi A, Brickman R, 2009. A study of the overall heat transfer coefficient of greenhouse cladding materials with thermal screens using the hot box method. Polymer Testing 28: 470-474. https://doi.org/10.1016/j.polymertesting.2009.02.006
Hwang YY, Lee JW, Lee HW, 2013. Estimation of overall heat transfer coefficient for single layer covering in greenhouse. Prot Hortic Plant Factor 22: 108-115. [in Korean]. https://doi.org/10.12791/KSBEC.2013.22.2.108
Klein S, 2012. Trnsys 17 manual: A transient system simulation program. Solar Energy Laboratory. University of Wisconsin, Madison: WI, USA.
Kus H, Özkan E, Göcer Ö, Edis E, 2013. Hot box measurements of pumice aggregate concrete hollow block walls. Construct Build Mat 38: 837-845. https://doi.org/10.1016/j.conbuildmat.2012.09.053
Lee JW, Kim DK, Lee HW, 2015. A numerical study for calculation of overall heat transfer coefficient of double layers covering and insulation material for greenhouse. Curr Res Agric Life Sci 33: 41-47.
Mahapatra K, 2015. Energy use and co2 emission of new residential buildings built under specific requirements – the case of växjö municipality, sweden. Appl Energ 152: 31-38. https://doi.org/10.1016/j.apenergy.2015.04.089
McAdams WH, 1954. Heat Transmission, 3rd edn. McGrawHill, NY.
Nijskens J, Deltour J, Coutisse S, Nisen A, 1984. Heat transfer through covering materials of greenhouses. Agr Forest Meteorol 33: 193-214. https://doi.org/10.1016/0168-1923(84)90070-4
Öztürk HH, 2005. Experimental evaluation of energy and exergy efficiency of a seasonal latent heat storage system for greenhouse heating. Energ Convers Manag 46: 1523-1542. https://doi.org/10.1016/j.enconman.2004.07.001
Pulselli RM, Simoncini E, Marchettini N, 2009. Energy and emergy based cost–benefit evaluation of building envelopes relative to geographical location and climate. Build Environ 44: 920-928. https://doi.org/10.1016/j.buildenv.2008.06.009
Rasheed A, Lee JW, Lee HW, 2015. A review of greenhouse energy management by using building energy simulation. Prot Hortic Plant Factor 24: 317-325. https://doi.org/10.12791/KSBEC.2015.24.4.317
Valera Martinez D, Molina Aiz F, Martinez A, 2008. Protocolo de auditoría energética en invernaderos. Auditoría energética de un invernadero para cultivo de flor cortada en mendigorría, Instituto para la Diversificación y Ahorro de la Energía, Madrid [in Spanish].
Watmuff J, Charters W, Proctor D, 1977. Solar and wind induced external coefficients-solar collectors. Coop Mediterr Energ Sol 1: 56.
Yang SH, Lee CG, Lee WK, Ashtiani AA, Kim JY, Lee SD, Rhee JY, 2012. Heating and cooling system for utilization of surplus air thermal energy in greenhouse and its control logic. J Biosyst Eng 37: 19-27. https://doi.org/10.5307/JBE.2012.37.1.019
Zhang H, Lei SL, 2012. An assessment framework for the renovation of existing residential buildings regarding environmental efficiency. Procedia - Social and Behavioral Sciences 68: 549-563. https://doi.org/10.1016/j.sbspro.2012.12.248
Zhou S, Zhao J, 2013. Optimum combinations of building envelop energy-saving technologies for office buildings in different climatic regions of china. Energ Build 57: 103-109. https://doi.org/10.1016/j.enbuild.2012.11.019
© CSIC. Manuscripts published in both the printed and online versions of this Journal are the property of Consejo Superior de Investigaciones Científicas, and quoting this source is a requirement for any partial or full reproduction.
All contents of this electronic edition, except where otherwise noted, are distributed under a “Creative Commons Attribution 4.0 International” (CC BY 4.0) License. You may read here the basic information and the legal text of the license. The indication of the CC BY 4.0 License must be expressly stated in this way when necessary.
Self-archiving in repositories, personal webpages or similar, of any version other than the published by the Editor, is not allowed.