Experimental results and modelling of humidity control strategies for greenhouses in continental and coastal settings in the Mediterranean region. II: Modelling of strategies
Resumen
Strategies for humidity control —with and without heating— were evaluated via simulations performed with apreviously developed model (see accompanying paper, this issue, part I). With heating, the best strategy combined the
use of a humidity setpoint with step control of the roof window, increasing the ventilation in line with the outside
temperature. Without heating, the best strategy again combined the use of a humidity setpoint with step control of the
roof window, but required ventilation to be increased in line with the inside air temperature
Descargas
© CSIC. Los originales publicados en las ediciones impresa y electrónica de esta Revista son propiedad del Consejo Superior de Investigaciones Científicas, siendo necesario citar la procedencia en cualquier reproducción parcial o total.
Salvo indicación contraria, todos los contenidos de la edición electrónica se distribuyen bajo una licencia de uso y distribución “Creative Commons Reconocimiento 4.0 Internacional ” (CC BY 4.0). Puede consultar desde aquí la versión informativa y el texto legal de la licencia. Esta circunstancia ha de hacerse constar expresamente de esta forma cuando sea necesario.